Entities subjected to the standard

Buildings affected by fire safety regulations

The use of wooden elements treated with fire-retardant coatings is always mandatory for premises requiring a CPI (Fire Prevention Certificate). Such structures are categorised according to the table below, which classifies premises based on visitor numbers, movement patterns and familiarity with the building:

Scorri la tabella
Types of intended use Lrisk
School gym A1
Office not open to the public, canteen, classroom, company meeting room, archive, book storage room A2
Commercial wholesale business, private garage A2-A3
Kitchen, school workshop, generator sets, heating systems, server room A3
Manufacturing facilities, craft workshops, processing plants, research laboratories, warehouses, mechanical workshops A1-A4
Storage of hazardous substances or mixtures A4
Art gallery, waiting room, café, restaurant, doctor’s office, surgery B1-B2
Office open to the public, sports centre, conference hall open to the public, nightclub, museum, theatre, cinema, entertainment venue B2
Library reading area, retail premises, exhibition space, public car park, car showroom B2-B3
Domestic property Ci2
Dormitory, halls of residence, student accommodation Cii2
Mountain hut Ciii1-Ciii2
Hotel room/td> Ciii2
Hospital stay, intensive care, operating theatre D2
Railway station, airport, underground station E2

Buildings
classification

In Italy, the Fire Service is the body responsible for issuing the Fire Prevention Certificate (CPI). In their assessment, the Fire Service identifies the risks arising from the quantity of combustible material present (fire load) and the number of people present. Based on these considerations, the Fire Service classifies premises and activities in ascending order of risk.
In accordance with the RTO (Horizontal Technical Regulation), which applies to every activity concerned, the relevant RTV (Vertical Technical Regulation) will be followed for each category in order to adapt the standard to the actual needs of the sector (e.g. RTV for tourist accommodation and hotel businesses)

Safety measures

Following the risk assessment, designers and manufacturers must implement one or more measures aimed at reducing the likelihood of fires occurring. These measures involve both active and passive protection.

Active protections
They require human intervention.
E.g. sprinklers, fire extinguishers, emergency exits, evacuation systems, smoke detectors, etc.

Passive protections
They are designed to minimise the effects of a fire by slowing down the spread of flames and the build-up of smoke without the need for human intervention.
E.g. fire-retardant and intumescent paints, plasters, panels, fire doors, etc.

Every structure made from a material classified as passive fire protection must meet a specified fire resistance or fire reaction class.

Fire resistance it’s a characteristic specific to structural elements, fire compartments or fire doors.

Fire reaction it’s a characteristic feature of wall coverings and furnishings.

Safety measures

Scorri il diagramma
Fire
prevention
Passive protection
Active protection
Safety distances
Fire behaviour of materials,
fire doors, fire barriers
and fire compartments
Reaction
to fire
ITALY
DM 26/06/1984
DM 06/03/1992
UNI 8456 - UNI 8457
UNI 9174 - UNI 9796
EUROPE
DM 2024/3110 (ex 305/11)
DM 10/03/2005
DM 25/10/2007
EN 13501-1
EN ISO 1182 - EN ISO 1716
EN 11925-2
EN 13823
EN 9239
Resistance
to fire
EUROPE
DM 2024/3110 (ex 305/11)
DM 16/02/2007
DM 09/03/2007
EN 13501-2
EN 13381
EN 950X
Sprinklers
Fire alarms
Fire extinguishers

Request a consultation with the experts at Renner Italia. We’ll find the right fire-retardant or intumescent solution for you.

This field is for validation purposes and should be left unchanged.
Name and surname(Required)